Search results for "Dental prosthesis design"
showing 10 items of 62 documents
In vitro comparison of primary stability of two implant designs in D3 bone
2016
Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…
Influence of short implants geometry on primary stability.
2018
Background A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants. Material and Methods Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in 30 randomly selected bovine ribs. PS was assessed in implant stability quotients (ISQ) and periotest values (PV) with Osstell™ and Periotest® devices, respectively. Computed tomographies of the ribs were taken and bone quality was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Kor…
Influence of supracrestal tissue attachment thickness on radiographic bone level around dental implants: A systematic review and meta-analysis.
2019
The present systematic review and meta-analysis was carried out to determine the extent to which supracrestal tissue attachment (STA) thickness affects marginal bone loss (MBL) around dental implants. An electronic search was conducted in PubMed (MEDLINE), EMBASE, and complementary sources covering the period up to June 2018. The studies were meta-analyzed based on implant position with respect to the alveolar bone crest (crestal/supracrestal). The MBL values were categorized according to STA width (thick/thin). Of the 1062 eligible titles, nine articles were included in the review. The implants were positioned crestal or supracrestal with respect to the alveolar ridge. The difference betwe…
Fixed dental prostheses with vertical tooth preparations without finish lines: A report of two patients
2016
Tooth abutments can be prepared to receive fixed dental prostheses with different types of finish lines. The literature reports different complications arising from tooth preparation techniques, including gingival recession. Vertical preparation without a finish line is a technique whereby the abutments are prepared by introducing a diamond rotary instrument into the sulcus to eliminate the cementoenamel junction and to create a new prosthetic cementoenamel junction determined by the prosthetic margin. This article describes 2 patients whose dental abutments were prepared to receive ceramic restorations using vertical preparation without a finish line.
Maintenance of marginal bone support and soft tissue esthetics at immediately provisionalized OsseoSpeed implants placed into extraction sites: 2-yea…
2012
Background Placement of implants into extraction sockets targets the maintenance of peri-implant hard and soft tissue structures and the support of a natural and esthetic contour. The main advantages of immediate implant insertion in comparison with delayed implant placement protocols are as follows: a reduced treatment time, less number of sessions, and, thus, the less invasive procedure. This study examines the clinical performance (survival rate, marginal bone levels and Pink Esthetic Score [PES]) of OsseoSpeed™ implants placed into extraction sockets with immediate provisionalization in the anterior maxilla after a follow-up of at least 12 months. Methods Twenty patients received a tota…
Clinical and esthetic outcome with immediate insertion and provisionalization with or without connective tissue grafting in presence of mucogingival …
2017
Background Recessions following immediate implant insertion are frequently reported in the literature. Data regarding implant installation in presence of mucogingival recessions are rare. Purpose This study observes soft tissue level changes following immediate implant insertion and provisionalization of implants with or without connective tissue grafts in the anterior maxilla in patients with initial mucogingival recession within a follow-up period between one and eight years. Materials and methods Twenty-six patients with marginal gingival recessions, which were designated for extraction and immediate implant insertion in the anterior zone of the maxilla (13-23), were included. Out of a l…
Immediately provisionalized OsseoSpeed(™) Profile implants inserted into extraction sockets: 3-year results.
2015
Objectives A sloped shoulder might improve the congruence between extraction socket and dental implant and may add to a better circumferential support of the peri-implant structures. Therefore, this study evaluates the 3-year clinical outcome (survival and success rates, marginal bone levels, and Pink Esthetic Score (PES)) of immediately inserted and provisionalized OsseoSpeed(™) Profile implants in the anterior maxilla. Material and methods Twenty-one implants were inserted in 16 patients. All implants were immediately placed into extraction sites with and without facial bone deficiencies. A flapless procedure was utilized, and the implants were provisionalized immediately. Facial gaps wer…
Effect of implant macro-design on primary stability: A prospective clinical study
2016
Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…
Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible
2011
Objectives: Short implants have become an interesting alternative to bone augmentation in dental implantology. Design of shorter implants and longer surveillance times are a current research issue. The goal of this study was to show the survival rates of short implants below 9 mm in the partly edentulous mandibular premolar and molar regions with fixed prosthetics. Marginal vertical and 2D bone loss was evaluated additionally. Different implant designs are orientationally evaluated. Material and Methods: A total of 247 dental implants with fixed prosthetics (crowns and bridges) in the premolar and molar region of the mandible were evaluated; 47 implants were 9 mm or shorter. Patient data we…
Histological differences in the adherence of connective tissue to laser-treated abutments and standard abutments for dental implants. An experimental…
2017
Background The goal of the current study is to assess the difference in connective tissue adherence to laser microtextured versus machined titanium abutments. Material and Methods Six patients were selected and each of them received 2 implants, one combined with a laser treated abutment and one with a machined abutment. After three months, the abutments were retrieved together with their surrounding gingival tissue for histological analysis. Qualitative and quantitative evaluation of microscopical images was performed to assess the presence or absence of adherence between the soft tissues and the abutment, and the percentage of soft tissue adhered to the two different surfaces. Results Inti…